Parent Topic: PARAMETERS

TIMEMULT

This parameter is only applicable to radiometric correction. It specifies a multiplication factor which can be used to increase the search time interval in which AVHRRAD tries to look for the exact starting scan date of the input image. The starting scan date refers to the exact instant just before the top-left pixel in the input image was scanned. By default, TIMEMULT is set to 1, which indicates that a default search interval of 60 minutes should be used.

 EASI>TIMEMULT=        | Defaults to a search interval of 60 minutes
 EASI>TIMEMULT=2       | Use a search interval of 120 minutes
AVHRRAD looks for date and time information in the text segment of the input PCIDSK file. It uses this date as an approximation to the exact starting scan date. The format of the date information in the text segment is described in the text segment format section.


Parent Topic: PARAMETERS